品牌
生产厂家厂商性质
北京市所在地
VPX电源模块原厂新货3U600W
1.1 Key Features
? Compliant to VITA 62 baseline specification
? Up to 715 Wmax. Power *
? 600 W over all
? up to 21A for +12V :VS1
? up to 50A for +3.3V :VS2
? up to 40A for +5V :VS3
? +12V / -12V AUX 4.2A
? +3V3 AUX 7A
? up to 92% efficiency
? -40 to +85°C Operating Temperature **
? Voltage sense controlled ***
? 18 – 35 V DC INPUT
* Derating: ~2% Wattage per Kelvin from 40°C on **
** At hottest outer case temperature / wedge lock edge temp. values in work
*** Over Voltage, Under Voltage, Over Current, Over Temperature
Shutdown control over each power rail, common control via VITA62 control bus
? Storage Temperature: -40°C to +100°C
? Weight: 0.6kg/1.23 Lbs
? Isolation Voltage: 500V
VPX电源模块原厂新货3U600W
All voltage ZVS converters are isolated (1500V isolation voltage) and fed via a common Filter Network from
the same 28V main supply (18V – 35V, shortly 36V). 3V3aux is not independent but protected by a
resettable fuse (PTC). All individual output voltages (6x) are sensed by window comparators for over- and
under voltages which are monitored from a central control logic device (CPLD). Any failure on the output
voltages are signaled on the front panel by corresponding FAIL LEDs and lead to a switch off of all voltages
(by default). If all internals are normal the blue READY LED is working. Figure 1 show gives an overview
over the front panel elements.