WIKA 55.831 带电接点的双金属温度计 不锈钢 IP65 表圆100 160mm

55.831WIKA 55.831 带电接点的双金属温度计 不锈钢 IP65 表圆100 160mm

参考价: 面议

具体成交价以合同协议为准
2022-03-27 08:03:23
424
产品属性
关闭
卓尔瑞华(北京)科技有限公司

卓尔瑞华(北京)科技有限公司

免费会员
收藏

组合推荐相似产品

产品简介

WIKA 55.831 带电接点的双金属温度计 不锈钢 IP65 表圆100 160mm

详细介绍

 

类型: 电接点双金属温度计 表面直径: 100 160(mm)
型号: 55.831 结构型式: 径向型
精度等级: 1 品牌: WIKA/威卡
加工定制: 测量范围: -70-600(℃)

WIKA 55.831 带电接点的双金属温度计 不锈钢 IP65 表圆100 160mm

Bimetal thermometer with switch contacts
Model 55, stainless steel version



Bimetal thermometer with switch contacts, model 55

 

 

  Applications
   ■ Control and regulation of industrial processes
   ■ Monitoring of plant and switching of electric circuits
   ■ Chemical industry, petrochemical industry, process technology and food industry
   ■ For aggressive medium

  Special features
   ■ High reliability and long service life
   ■ Universal application
   ■ Case and stem material stainless steel
   ■ Gauges with inductive contacts for use in hazardous areas with ATEX approval
   ■ Gauges with electronic contacts for PLC applications

 

   Description
   Wherever the process temperature has to be indicated locally, and, at the same time, circuits are to be made or broken, the bimetal thermometer with switch contact can be used.
   Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the position of the instrument pointer. The switch contacts are adjustable over the full extent of the scale range. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
   The set pointer can be adjusted using a detachable adjustment key (mounted to the junction box) in the window.

 

   Switch contacts consisting of several contacts can also be set to a single setpoint. Contact actuation is made when the actual value pointer travels beyond or below the desired set value.
   As switch contacts sliding contacts, inductive contacts - for requirements to ATEX - or electronic contacts for triggering a PLC are available.
   For further information on the different switch contacts please see data sheet AC 08.01.

 

  

 

 