品牌
经销商厂商性质
广州市所在地
The complete BK MIKRO system includes
The wand of the scanner inspects object positions or ranges potential-free according to the machine cycle. A micro-computer based control unit triggers the wand movement by an external signal or a signal from the PROFIBUS-Master (PLC). The scanning result is then compared to the nominal value in the control unit (by means of “teach-in” or programmed parameters) and passed on as “o.k.” or “k.o.” message via relay contacts (digital I/O) or via PROFIBUS to the machine control. Any deviation can trigger an instantaneous machine stop ensuring that the machine doesn't crash and also prevents bad parts from being manufactured.
From simple tool breakage monitoring in a single head machine to the control of a wide range of different tool lengths in the magazine of a machining center (including their correct storage) to the inspection of profiles with the highest scanning precision, BK MIKRO® offers all functions for checking production processes:
Nearly 30 years of experience, over 85,000 systems installed world-wide, more than 5 million scanning cycles per scanner and a 2-year warranty. Who can offer you more security?
BK MIKRO systems are produced in accordance with ISO Standard 9001 and meet all internationally required safety standards. They all dispose of the CE sign and UL approval.
BK MIKRO9 integrates almost all features of the known BK MIKRO systems. It is usable for tool monitoring and object or free space monitoring purposes.
The MIKRO9 system contents
The BK MIKRO9 models are suitable for a great variety of monitoring tasks:
Further Features:
Subject to technical modifications and amendments.
BK MIKRO91/92 Premium
BKM91:
|
Technical data
Housing | Insulation material, protection class II, built-in type |
Protection class | IP20 |
Dimensions | 22.6 mm x 99 mm x 113.6 mm |
Mounting | Profile rail 35 mm acc. DIN EN 50022 |
Power supply voltage | 24 VDC ±20 % PELV, Imax = 0,4 A |
Power consumption | Max. 10 VA |
Control voltage | 24 VDC ±20 % PELV |
Inputs | Galvanically isolated, input current approx. 5 mA, pulse duration 30 ms min. |
Switch outputs | 2x 30 VDC, 2 A max. |
Life cycle of relay | 105 switching cycles min. |
Connections |
|
Climate conditions | According class 3K3 acc. EN 50178 |
Ambient temperature | 0 °C up to +50 °C |
BK MIKRO93 Basic
|
Technical data
Housing | Insulation material, protection class II, built-in type |
Protection class | IP20 |
Dimensions | 22.6 mm x 99 mm x 113.6 mm |
Mounting | Profile rail 35 mm acc. DIN EN 50022 |
Power supply voltage | 24 VDC ±20 % PELV, Imax = 0,4 A |
Power consumption | Max. 10 VA |
Control voltage | 24 VDC ±20 % PELV |
Inputs | Galvanically isolated, input current approx. 5 mA, pulse duration 30 ms min. |
Switch outputs | 2x 30 VDC, 2 A max. |
Life cycle of relay | 105 switching cycles min. |
Connections |
|
Climate conditions | According class 3K3 acc. EN 50178 |
Ambient temperature | 0 °C up to +50 °C |
BK MIKRO9I/O Extension Module
|
Technical data
Housing | Insulation material, protection class II, built-in type |
Protection class | IP20 |
Dimensions | 22.6 mm x 99 mm x 113.6 mm |
Mounting | Profile rail 35 mm acc. DIN EN 50022 |
Control voltage | 24 VDC ±20 % PELV |
Inputs | Input current approx. 5 mA, pulse duration 30 ms min. |
Switch outputs | 2 high side switches with maximum output current 0.5 A |
Connections | Pluggable screw terminals for 10 inputs, 2 outputs (with voltage supply) |
Climate conditions | According class 3K3 acc. EN 50178 |
Ambient temperature | 0 °C up to +50 °C |
Subject to technical modifications and amendments.
| 63 04 242 |
| 63 04 243 |
| 63 04 244 |
| 63 04 247 |
| 63 04 245 |
| 63 04 249 |
| 63 04 252 |
| 63 04 250 |
| 63 04 251 |
| 63 04 237 |
| 63 04 234 |
| 63 04 235 |
| 62 04 279 |
| 62 04 251 |
| 62 04 253 |
| 62 04 252 |
| 62 04 257 |
| 62 04 294 |
| 62 04 295 |
| 62 04 293 |
Description / Bezeichnung | Article-No. |
| 63 04 206 |
| 63 04 210 |
| 59 08 027 |
| 59 08 028 |
| 59 08 029 |
Description / Bezeichnung | Article-No. |
| 63 04 220 |
| 63 04 234 |
| 63 04 235 |
| 62 04 248 |
| 62 04 250 |
| 62 04 249 |
| 62 04 210 |
| 62 04 211 |
| 62 04 212 |
| 62 04 213 |
Description / Bezeichnung | Article-No. |
| 63 04 237 |
| 62 04 260 |
| 62 04 262 |
| 62 04 251 |
| 62 04 253 |
| 62 04 252 |
Hinweis: Das Steuergerät BK MIKRO 8 PB ist nicht mehr verfügbar. Bitte setzen Sie das Nachfolgeprodukt Steuergerät BK MIKRO9 ein.
Description / Bezeichnung | Article-No. |
| 63 04 226 |
| 63 04 229 |
| 62 04 217 |
| 62 04 228 |
| 62 04 226 |
| 62 04 210 |
| 62 04 211 |
| 62 04 212 |
| 62 04 213 |
| 63 04 224 |
| 63 04 225 |
Description / Bezeichnung | Article-No. |
BKM Scanning wands / Tastnadeln (Standard) ø = 1,2 mm, l= 165 mm (10 pieces / 10 Stück) | 62 04 022 |
BKM Scanning wands / Tastnadeln ø = 1,2 mm, l= 250 mm (10 pieces / 10 Stück) | 62 04 216 |
BKM HSS Scanning wands / Tastnadeln ø = 1,2 mm, l= 165 mm (1 Stück) | 62 04 215 |
BKM HSS Scanning wands / Tastnadeln ø = 1,2 mm, l= 250 mm (1 piece / Stück) | 62 04 231 |
BKM Wand holder / Nadelhalter (Standard) -> TK 4 / TK 5 Axis / Achse ø = 4 mm, incl. wand / inkl. Nadel ø = 1,2 mm | 62 04 023 |
BKM Wand holder / Nadelhalter (small chips / kurzbrechende Späne) -> TK 4 / TK 5 Axis / Achse ø = 4 mm, incl. wand / inkl. Nadel ø = 1,2 mm | 62 04 214 |
BKM Wand holder / Nadelhalter (Standard) -> TK 7 / TK 8 Axis / Achse ø = 3 mm, incl. wand / inkl. Nadel ø = 1,2 mm | 62 04 026 |
BKM Wand holder / Nadelhalter (small chips / kurzbrechende Späne) -> TK 7 / TK 8 Axis / Achse ø = 3 mm, incl. wand / inkl. Nadel ø = 1,2 mm | 62 04 263 |
BKM Mounting bracket / BKM Montagehalter, ø 32 mm (-> BKM 4 / 5 / LIN) | 61 07 082 |
BKM Mounting bracket / BKM Montagehalter, ø 20 mm (-> BKM 7 / 8 / LIN) | 61 07 165 |
BKM Scanning wand with plate (120x15), ø 4 x 510 mm (1 piece) BKM Tastnadel mit Platte (120x15), ø 4 x 510 mm (1 Stück) | 62 04 279 |
BKM Scanning wand with plate (80x15), ø 3 x 380 mm (1 piece) BKM Tastnadel mit Platte (80x15), ø 3 x 380 mm (1 Stück) | 62 04 260 |
BKM Scanning wand with plate (65x15), ø 3 x 284 mm (1 piece) BKM Tastnadel mit Platte (65x15), ø 3 x 284 mm (1 Stück) | 62 04 262 |
BKM Balance weight (2 x ø 20 mm, 1 x ø 16 mm) BKM Gegengewichtsset (2 x ø 20 mm, 1 x ø 16 mm) | 62 04 282 |
BKM Scanner accessories (adapter, scanner tip, wand holder, wand) BKM Tastkopf-Zubehör (Adapter, Tastkopfspitze, Nadelhalter, Nadel) | 62 04 904 |
BKM air barrier adapter / Sperrluftadapter Axis / Achse ø = 3 mm, wand / Nadel ø = 3 mm (-> TK8) | 62 04 027 |
BKM air barrier adapter / Sperrluftadapter Axis / Achse ø = 3 mm, wand / Nadel ø = 1,2 mm (-> TK7 / TK8) | 62 04 028 |
BKM air barrier adapter / Sperrluftadapter Axis / Achse ø = 4 mm, wand / Nadel ø = 1,2 mm or 4 mm (-> TK 4 / TK 5) | 62 04 029 |
Subject to technical modifications and amendments. | Technische Änderungen vorbehalten.
Click on a thumbnail for viewing the image in detail (JavaScript required).
Bidirectional tool monitoring / broken tool detection | Broken tool detection | Broken tool detection in the magazine of a machine tool (mechanically protected wand) |
Broken tool detection in the magazine of a machine tool | <a title="Broken tool detection in the magazine" data-cke-saved-href="http://www.bk-mikro.com/img/werkzeugbruch/werkzeugbruchueberwachung.jpgrel=\lightbox" href="http://www.bk-mikro.com/img/werkzeugbruch/werkzeugbruchueberwachung.jpgrel=\lightbox" "=""> Broken tool detection in the magazine of a machine tool (tool tip) |
Functional Principle Tool Monitoring
Depending on the preset parameters in the control unit when a start signal is given from the machine control the wand rotates left or right until it reaches the tool. In this process it first approaches the monitoring range with maximum speed, then decelerates and scans the tool with the set intensity. Once the wand contacts the tool or goes past the point where the tool should be (broken tool) the wand returns to home position at maximum speed and outputs either and OK or KO signal.
By means of a preset angle the wand can be assigned a freely definable home position between two tools to be monitored. After the wand has reached this position the two toos can be scanned. The order of the scanning direction is also selectable.
广州市朝德机电设备有限公司
:
:郑杰克、向
: novosor : www.novosor.com
地址:广州市越秀区朝天路66号3F