UVOZ-3300C OZONE CONCENTRATION ANALYZER-Stainless shell
品牌
其他厂商性质
淄博市所在地
Technical parameters
Model: UVOZ-3300C
Measuring range: 0-300g/Nm3
Optional range: 0-400g/Nm3; 0-200g/Nm3; 0-100g/Nm3; 0-50g/Nm3; 0-10000ppm;
Light source life: about 30000-50000 hours;
Sampling method: positive pressure sampling, negative pressure sampling (optional);
Display interface: 4.3 inch touch screen operation interface (optional 7 inch touch screen);
Content interface: ozone concentration, temperature, pressure; (Customizable data recording)
Auxiliary functions: temperature compensation, pressure compensation;
Display unit: g/Nm3, mg/NL,% WT optional;
Display resolution: 0.01g/Nm3;
Gas flow: 0.5L ± 0.2L/min;
Input pressure:<>
Concentration error: ≤ 0.5% FS;
Linear error: ≤ 0.5% FS;
Zero drift:<± 0.3%.="">±>
Response time: signal 0.03 seconds, display 0.3 seconds;
Ambient temperature: - 20~50 ℃;
Pipeline interface mode: quick screwing (stainless steel);
Diameter of series connection sample: Φ 8 (8mm * 6mm) (optional);
Bypass sampling diameter: Φ 6(6mm*4mm);
Communication mode: RS-485;
Output mode: 4-20mA (active);
Power supply: AC 110-220V;
Size: 230mm high × 330mm wide × 150mm deep;
Note: 1mg/L=1g/m3=467PPM;
Free warranty: 24 months (host sensor);
Note: Standard configuration (built-in): anti-corrosion flowmeter, ozone exhaust gas destructor, ozone intake (dust) filter.
3、 Product features:
Measurement features: patented technology, dual optical path UV absorption method principle, foreign long life UV LED light source, continuous operation, ensuring the stability of the detection concentration.
Test method: dual optical path UV optical absorption method, long life light source system, ensuring measurement accuracy.
Real-time calibration: With an automatic zero calibration function, the system will automatically complete the zero calibration operation when ozone is introduced.
Measurement principle: Accurate measurement based on Lambert Beer's law and the principle of photometric absorption.
Light source system: Foreign long-life UV LED light source system, with a two-year free warranty.
Usage: It is rainproof and can be installed indoors and outdoors. It is equipped with waterproof power supply and signal terminals.
Light cell system: Separate light cell and gas chamber structure, no leakage, high pressure resistance, and resistance to large flow sampling gas impact.
Intelligent compensation: Built-in temperature and pressure compensation with display, with automatic light source compensation function.
Operation mode: The user can select manual and automatic zero calibration based on the operation status, and can set the automatic zero calibration time.
Display unit: g/Nm3, mg/NL, WT% can be customized and optional.
Data display: Color touch screen, customizable data recording function.
Output function: 4-20mA, RS485 communication, two groups of alarm point output, electronic flow-meter input, etc.
Standard configuration: anti-corrosion flow-meter, ozone exhaust gas destructor, ozone intake filter.
Patent information of Shandong ZHIPRER M&C Tech Cor. LTD. involved in and adopted by this ozone concentration analyzer:
Patent name: An ozone concentration analyzer device with automatic zero calibration function
Patent name: Ozone concentration analyzer optical cell absorption chamber device
Patent name: An ozone concentration analyzer with gas split flow automatic zero calibration function
The above patents are proprietary intellectual property rights owned by the company, and patented products that have been intensively researched and developed must be prosecuted for counterfeiting