品牌
其他厂商性质
苏州市所在地
Super Silent Version:
机型
Length 长 | x | Width 宽 | x | Height 高 | Weight Appro. 重量约 |
1480 mm | x | 830 mm | x | 1515 mm | 560 kg |
压缩机主机技术参数:
Medium : 压缩介质 | Air |
Ambient Temperature : 环境温度 | +5 to +45°C |
Nominal Pressure max. : 公称压力 | 365 bar adjusted by safety valve |
Working Pressure : 工作压力 | 90-350 bar adjustable by final pressure sensor |
Capacity : 流量 | 610 l/min |
| Volume flow rate acc. to ISO 1217 |
Speed : 转速 | 1320 1/min |
Number of Compression stages : 压缩级数 | 4 |
Number of Cylinders : 汽缸数 | 4 |
Stroke : 活塞冲程 | 50 mm |
Mean piston speed : 平均活塞速度 | 2,2 m/s |
Power consumption at max. pressure 压力时的功率消耗 | 12 kW |
Drive : 驱动方式 | V-belt |
Cooling Airflow, min. required approx. 所需的最少冷却空气量 | 5400 m³/h |
Technical Data for Prime Mover:
驱动电机的技术参数:
Type : 型号 | three phase electric motor |
Power : 功率 | 15 kW |
Speed : 转速 | 2850 1/min |
Enclosure : 防护等级 | IP55 |
Frequency : 频率 | 50 Hz |
COMPRESSORBLOCK
· 压缩机主机
- Oil pump for forced-feed lubrication with oil filter
油泵带油滤器作注油式润滑
- Oil sump content: 6,0l
- 油池容量: 6.0升
- Micronic intake filter
进气滤芯
- Interstage coolers, air cooled after each stage
每级压缩后都设有冷却器
- Aftercooler, air cooled, outlet temp. approx. 10-15 °C above ambient temp.
压缩气体经过冷却器后的温度大约高于环境温度10-15 °C
- Intermediate oil/water separators after each stage (exept 1st stage)
每级压缩后都设有中级水油分离器 (除级外)
- Final oil/water separator
终级水油分离器
- Safety valves after each stage
每级压缩后都设有安全阀
- Final pressure safety valve
终级安全阀
- Pressure maintaining and check valve before compressor outlet
压缩机出口前设有压力维持阀及单向阀
- Final pressure gauge
终级安全阀
- First oil filling with final test
压缩机已加注润滑油并经过整机运行测试
- Oil change 2000 hours or 2 years whichever comes first
润滑油更换时间为运行2000小时或两年(二者以先到为准)
德国宝华风冷重栽高压压缩机主机(图片供参考)
· AUTOMATIC CONDENSATE DRAIN DEVICE
· 冷凝水自动排放器
- Drains all oil/water separators during compressor operation
在压缩机运作过程中会排放所有水油分离器的冷凝水
- Draining interval is adjustable (standard: drains all 15min for 6sec)
可调整每次排放间隔时间(标准: 每15分钟排放6秒)
- Unloaded start integrated (automatic drain during shut-down of the unit)
不负载起动 (冷凝水会自动排放当压缩机关掉时)
- Condensate collecting tank 10l with silencer and filter for exhaust gas
排气设有消音器及过滤器的10升收集箱
· CONFIGURATION AND STYLE OF UNIT
· 压缩机构造及款式
- Vertical arrangement of the unit on solid base frame
压缩机垂直安装在稳固底架上
- Shock absorbers for free standing installation
设有减震器的独立式设置
- Super Silent Housing with removable side doors
Reduction of noise level to approx.
72 dB(A) ± 2 dB(A) (ISO 3744) 7,5kW and higher
- 可选择: 可移除的外壳边门, 减少的程度噪音大约:
72 dB(A) ± 2 dB(A) (ISO 3744) 7,5kW 或更高
- Control panel and display integrated in compressor housing
仪表板及监控原件装在压缩机外壳上
- Electrical connection: Cable length 5m;
电线连接:5米电线
- High pressure outlet: fitting 8S for pipe ? 8mm
高压出口:8mm管道8S连接
- Colour颜色: Compressor block压缩机主机: silver银色
Base frame 底架: RAL 7024 graphite grey石墨灰色
Compressor housing压缩机外壳: RAL 9006 white aluminium/cyan铝白色/蓝色
Pressure vessels 压力容器(i.a.): RAL 7024 graphite grey 石墨灰色
PURIFICATION SYSTEM P 61 (Integration in the compressor housing)
P61过滤系统 (集成于压缩机内 )
Scope of delivery:
供货范围
Check valve
止回阀
Bleed valve with pressure gauge
带有压力表的排出阀
1x Filterhousing with longlife-filter cartridge 20“
1个带有高效滤芯20的滤筒
Pressure maintaining- and check valve
保压阀和止回阀
Key for filter housing
用于滤筒的专门工具
Air quality:
气体质量
Values refer to ambient temperature: 20°C 参考的环境温度:20度 | Quality class according to 质量等级根据ISO8573-1:2010 | |
Pressure dew point (at 90bar - 500bar): 压力露点(在90巴-500巴之间) |
-20°C |
|
Atmospheric dew point acc. to working pressure 从工作压力释放到常压下的水含量: at 90bar: at 300bar: at 500bar: |
- 62°C - 69°C - 71°C | |
Water content after expansion from working pressure: 从工作压力释放到常压下的水含量: 90bar: 300bar: 500bar: |
< 10 mg/Nm³ (14ppmV) < 3,2 mg/Nm³ (4,3ppmV) < 2,4 mg/Nm³ (3,2ppmV) |
|
Oil content : 含油量: |
< 0,1 mg/Nm³ |
|
SECURUS AIR PURITY CONTROL DEVICE
SECURUS 滤芯饱和度监控装置
The SECURUS system controls continously the saturation
of the filter cartridge by measuring the air humidity in the
molecular sieve layer and gives a warning signal before
a cartridge change is necessary.
SECURUS系统可以通过测量分子筛湿度来持续监控
滤芯饱和程度;在滤芯真正需要更换之前,SECURUS
会给出信号。
At 99% exploitation of filter cartridge capacity the
SECURUS stops the compressor unit automatically.
在滤芯99%使用完之前,SECURUS会使压缩机
自动停机。
The following operating conditions are indicated on the display:
以下运行工况会在显示器上体现出来:
GREEN light on: cartridge is okay
绿灯亮: 滤芯正常
YELLOW light flashing: pre-warning of cartridge saturation
黄灯闪烁:滤芯饱和前的预警
RED light flashing: cartridge is saturated compressor is switched off.