品牌
其他厂商性质
深圳市所在地
产 品 特 色 音讯广播标准 FM/RDS/TMC IBOC - HD Radio XM Satellite Radio Sirius Radio DAB 卫星导航标准 GPS CNSS CLONASS GALILEO 电视广播标准 DVB-T/H DVB-T2 DVB-SH CMMB ISDB-T ISDB-Tsb MediaFLO ATSC-MH T-DMB DVB-C DVB-C2 OPEN Cable ATSC DTMB NTSC PAL SECAM | |
检测项目: | |
• 频率支持频率范围 25MHz到2.7GHz频率可涵盖全广播频道与各标准卫星导航讯号 | |
• 高达20MHz的录制频宽 满足各种应用 | |
• 同等级取样率100MS/s | |
• 提供外接式硬盘eSATA接口无限扩充硬盘容量 | |
• 可抽换式2.5吋SATA硬盘增加使用便利度 | |
• 超越同级支持GPS位置记录 | |
• 业界射频档案分段区间播放功能 | |
• 使用便利性10.2吋触控屏幕 | |
• 频谱marker强化功能 | |
• 射频档案支持MATLAB分析 规格 MP7200 2.7 GHz 射频纪录器 |
MP7200 2.7 GHz 射频产生器
Frequency
Frequency range ..............................................................25MHz to 2.7 GHz
Real-time bandwidth......................................................................1~20 MHz
Frequency resolution………………………….......................1KHz step minimum
Resolution bandwidth (RBW)......................Fully adjustable (100 Hz to 3MHz)
Warm-up time (typical)……………………….....................................30 minutes
Temperature stability ........................................................±20 ppb maximum
Initial achievable accuracy.................................................±50 ppb maximum
Aging
Per year..........................................................................±100 ppb maximum
Per day…………………………………………............................±1 ppb maximum
Initial achievable accuracy.................................................±50 ppb maximum
Spectral purity
Phase Noise@1 kHz offset, 1GHz...............................................<-80 dBc/Hz
RF input Spurious Response……………………….......................<-90 dBm
Noise Density
Passive Port (Gain : 40dB/100MHz)………………………………….<-160dBm/Hz
Active Port (Gain : 20dB/100MHz)…………………………………....<-145dBm/Hz
Amplitude(Passive Port)
Input level Accuracy ( 15 to 35°C )...................................................<+/- 1dB
Input signal range@CW mode..........................................-145 dBm~-30 dBm
Gain Range..................................................................0~+40 dB@ 5dB step
Input level resolution……………………………………………………...........0.01dB
Maximum DC input..........................................................................±50 VDC
Group delay.............................................................................30 ns Typical
Amplitude (Active Port)
Input level Accuracy ( 15 to 35°C )...................................................<+/- 1dB
Input signal range @CW mode.........................................-135 dBm~+10 dBm
Gain Range.................................................................-5~+20 dB@ 5dB step
Input level resolution……………………………………………………...........0.01dB
DC Voltage Output Range.................................................0~+10V@0.1Vstep
Group delay.............................................................................30 ns Typical
RF input
Passive RF input ............................................50ohm , AC-coupled N female
Active RF input ...............................................50ohm , DC-coupled N female
IF Band
Resolution.........................................................................................14 bits
Sample rate....................................................................................100MS/s
Storage
Storage........................................................................................640 GByte
Calibration
Calibration .........................................................................................1 year
Environment
Operating temperature .................................................................0 to +50°C
Relative humidity...........................................................................10 to 90%
Storage temperature ..................................................................-20 to 70 °C
Relative humidity.............................................................................5 to 95%
Frequency Characteristics
Frequency range .................................................................25MHz to 2.7 GHz
Real-time bandwidth (Digital vector modulation bandwidth) .....20 MHz maximum
Frequency resolution…………………………………………….....1KHz step minimum
Warm-up time (typical) ....................................................................30 minutes
Temperature stability…………………………………………….......±20 ppb maximum
Per year........................................................……………......±100 ppb maximum
Per day .................................................................................±1 ppb maximum
Initial achievable accuracy....................................................±50 ppb maximum
Spectral purity
Phase Noise@1KHz offset, 1Ghz…………………………….................<-80 dBc/Hz
Spurious Responses
Second harmonic……..……………………....………………………............< –40 dBc
Output third-order distortion (IMD)
(two -13 dBm tones, >200 kHz apart)………………...…………......-70 dBc Typical
LO leakage……………………..…………………………………….................<-80dBm
RF Output Characteristics
Output power range .........................................................-145 dBm to -10 dBm
Amplitude resolution…………………………………................0.1 dB step minimum
Amplitude Accuracy………………………………...........<+/-1 dB -100dBm~-10dBm
<+/-2 dB <-100dBm
Output Impedance………………………………………………………...............50 ohm
Overload protection on RF output
Maximum reverse RF power .......................................................1 W maximum
Maximum DC input.............................................................................±50 VDC
Noise Floor@1GHz
-40dBm output power ………………………….……………......<-150dBm/Hz Typical
-50dBm output power………………………………………….....<-160dBm/Hz Typical
Flatness
IF Band(20MHz) flatness………………………………………….............1 dB Typical
Group delay…………………………………………………………….........30 ns Typical
RF Output
RF Output…… ....................................................50ohm , AC-coupled N female
IF Band
Resolution.............................................................................................14 bits
Sample rate........................................................................................100MS/s
Calibration
Calibration ............................................................................................1 year
Operating Environment
Operating temperature ....................................................................0 to +50°C
Relative humidity...............................................................................10 to 90%
Storage temperature .....................................................................-20 to 70 °C
Relative humidity................................................................................5 to 95%
Power
AC…………………….....................................................................100V to 240V
Mechanical
Dimensions……………........................................(L):34.6x(W):30.2x(H):22.9 cm
Weight…………..........................................................................approx 12 kgw