西门子SM1223数字量输入/输出模块,西门子SM1223数字量输入/输出模块销售,价格,代理,介绍
应用领域
数字量 I/O 模块允许:
这为用户提供了下列优势:
功能
SM 1223 数字量输入/输出信号模块
德国* 现货销售 质保一年 欢迎询价
SIEMENS 上海翰粤自动化系统有限公司
黄政武(销售工程师) | |
手 机 | |
2880585022 | |
电 话 |
技术规格 订货号
6ES7223-1BH32-0XB0 SIMATIC S7-1200, SM1223 数字量输入输出模块 8输入24V DC/ 8输出24V DC |
6ES7223-1BL32-0XB0 SIMATIC S7-1200, SM1223 数字量输入输出模块 16输入24V DC/ 16输出24V DC |
6ES7223-1PH32-0XB0 SIMATIC S7-1200, SM1223 数字量输入输出模块 8输入24V DC/ 8输出继电器 |
6ES7223-1PL32-0XB0 SIMATIC S7-1200, SM1223 数字量输入输出模块 16输入24V DC/ 16输出继电器 |
6ES7223-1QH32-0XB0 SIMATIC S7-1200, SM1223 数字量输入输出模块 8输入120/230V AC/ 8输出继电器 |
Order number | 6ES7223-1BH32-0XB0 | 6ES7223-1BL32-0XB0 | 6ES7223-1PH32-0XB0 | 6ES7223-1PL32-0XB0 | 6ES7223-1QH32-0XB0 | |
---|---|---|---|---|---|---|
| DIGITAL I/O SM 1223, 8 DI / 8 DO | DIGITAL I/O SM 1223, 16DI/16DO | DIGITAL I/O SM 1223, 8DI/8DO | DIGITAL I/O SM 1223, 16DI/16DO | DIGITAL I/O SM 1223, 8DI AC/ 8DO RLY | |
General information |
|
|
|
|
| |
Product type designation | SM 1223 DI 8x24 VDC, DQ 8x24 VDC | SM 1223 DI 16x24 VDC, DQ 16x24 VDC | SM 1223 DI 8x24 VDC, DQ 8xRelay | SM 1223 DI 16x24 VDC, DQ 16xRelay | 120/230 V AC SM223 DIx8/DQx8 RLY | |
Supply voltage |
|
|
|
|
| |
Rated value (DC) |
|
|
|
|
| |
| Yes | Yes | Yes | Yes | Yes | |
permissible range, lower limit (DC) | 20.4 V | 20.4 V | 20.4 V | 20.4 V | 20.4 V | |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V | 28.8 V | |
Input current |
|
|
|
|
| |
from backplane bus 5 V DC, max. | 145 mA | 185 mA | 145 mA | 180 mA | 120 mA | |
Digital inputs |
|
|
|
|
| |
| 4 mA; per channel | 4 mA; per channel | 4 mA/input 11 mA/relay | 4 mA/input 11 mA/relay |
| |
Output voltage |
|
|
|
|
| |
Power supply to the transmitters |
|
|
|
|
| |
| Yes | Yes | Yes | Yes | Yes | |
Power loss |
|
|
|
|
| |
Power loss, typ. | 2.5 W | 4.5 W | 5.5 W | 10 W | 7.5 W | |
Digital inputs |
|
|
|
|
| |
Number of digital inputs | 8 | 16 | 8 | 16 | 8 | |
| 2 | 2 | 2 | 2 | 4 | |
Input characteristic curve in accordance with IEC 61131, type 1 | Yes | Yes | Yes | Yes | Yes | |
Number of simultaneously controllable inputs |
|
|
|
|
| |
all mounting positions |
|
|
|
|
| |
| 8 | 16 | 8 | 16 | 8 | |
horizontal installation |
|
|
|
|
| |
| 8 | 16 | 8 | 16 | 8 | |
| 8 | 16 | 8 | 16 | 8 | |
vertical installation |
|
|
|
|
| |
| 8 | 16 | 8 | 16 | 8 | |
Input voltage |
|
|
|
|
| |
| DC | DC | DC | DC | AC | |
| 24 V | 24 V | 24 V | 24 V |
| |
|
|
|
|
| 120/230V AC | |
| 5 V DC at 1 mA | 5 V DC at 1 mA | 5 V DC at 1 mA | 5 V DC at 1 mA | 20 V AC at 1 mA | |
| 15 VDC at 2.5 mA | 15 VDC at 2.5 mA | 15 VDC at 2.5 mA | 15 VDC at 2.5 mA | 79 V AC at 2.5 mA | |
Input current |
|
|
|
|
| |
| 1 mA | 1 mA | 1 mA | 1 mA | 1 mA | |
| 2.5 mA | 2.5 mA | 2.5 mA | 2.5 mA | 2.5 mA | |
| 4 mA | 4 mA | 4 mA | 4 mA | 9 mA | |
Input delay (for rated value of input voltage) |
|
|
|
|
| |
for standard inputs |
|
|
|
|
| |
| Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | |
for interrupt inputs |
|
|
|
|
| |
| Yes | Yes | Yes | Yes | Yes | |
Cable length |
|
|
|
|
| |
| 500 m | 500 m | 500 m | 500 m | 500 m | |
| 300 m | 300 m | 300 m | 300 m | 300 m | |
Digital outputs |
|
|
|
|
| |
Number of digital outputs | 8 | 16 | 8 | 16 | 8 | |
| 1 | 1 | 2 | 4 | 4 | |
Short-circuit protection | No; to be provided externally | No; to be provided externally | No; to be provided externally | No; to be provided externally | No; to be provided externally | |
Limitation of inductive shutdown voltage to | L+ (-48 V) | L+ (-48 V) |
|
|
| |
Switching capacity of the outputs |
|
|
|
|
| |
| 0.5 A | 0.5 A | 2 A | 2 A | 2 A | |
| 5 W | 5 W | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC | |
Output voltage |
|
|
|
|
| |
| 24 V | 24 V | 5 V DC to 30 V DC | 5 V DC to 30 V DC | 5 V DC to 30 V DC | |
|
|
| 5 V AC to 250 V AC | 5 V AC to 250 V AC | 5 V AC to 250 V AC | |
| 0.1 V; with 10 kOhm load | 0.1 V; with 10 kOhm load |
|
|
| |
| 20 V DC | 20 V DC |
|
|
| |
Output current |
|
|
|
|
| |
| 0.5 A | 0.5 A |
|
|
| |
| 0.5 A | 0.5 A | 2 A | 2 A | 2 A | |
| 10 µA | 10 µA |
|
|
| |
Output delay with resistive load |
|
|
|
|
| |
| 50 µs | 50 µs | 10 ms | 10 ms | 10 ms | |
| 200 µs | 200 µs | 10 ms | 10 ms | 10 ms | |
Total current of the outputs (per group) |
|
|
|
|
| |
horizontal installation |
|
|
|
|
| |
| 4 A; Current per mass | 8 A; Current per mass | 10 A; Current per mass | 8 A; Current per mass | 8 A; Current per mass | |
Relay outputs |
|
|
|
|
| |
|
|
| 8 | 16 | 8 | |
|
|
| 24 V | 24 V | 24 V | |
|
|
| mechanically 10 million, at rated load voltage 100 000 | mechanically 10 million, at rated load voltage 100 000 | mechanically 10 million, at rated load voltage 100 000 | |
Switching capacity of contacts |
|
|
|
|
| |
| 0.5 A | 0.5 A | 2 A | 2 A | 2 A | |
| 5 W | 5 W | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC | |
| 0.5 A | 0.5 A | 2 A | 2 A | 2 A | |
Cable length |
|
|
|
|
| |
| 500 m | 500 m | 500 m | 500 m | 500 m | |
| 150 m | 150 m | 150 m | 150 m | 150 m | |
Interrupts/diagnostics/status information |
|
|
|
|
| |
Alarms | Yes | Yes | Yes | Yes | Yes | |
Diagnostic functions | Yes | Yes | Yes | Yes | Yes | |
Alarms |
|
|
|
|
| |
| Yes | Yes | Yes | Yes | Yes | |
Diagnostic messages |
|
|
|
|
| |
| Yes |
| Yes | Yes |
| |
Diagnostics indication LED |
|
|
|
|
| |
| Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | |
Potential separation |
|
|
|
|
| |
Potential separation digital inputs |
|
|
|
|
| |
| 2 | 2 | 2 | 2 | 2 | |
Potential separation digital outputs |
|
|
|
|
| |
|
|
| Relays | Relays | Relays | |
| 1 | 1 | 2 | 4 | 2 | |
| 500 V AC | 500 V AC | 1500 V AC for 1 minute | 1500 V AC for 1 minute | 1500 V AC for 1 minute | |
Permissible potential difference |
|
|
|
|
| |
between different circuits |
|
| 750 V AC for 1 minute | 750 V AC for 1 minute | 750 V AC for 1 minute | |
Degree and class of protection |
|
|
|
|
| |
Degree of protection acc. to EN 60529 |
|
|
|
|
| |
| Yes | Yes | Yes | Yes | Yes | |
Standards, approvals, certificates |
|
|
|
|
| |
CE mark | Yes | Yes | Yes | Yes | Yes | |
CSA approval | Yes | Yes | Yes | Yes | Yes | |
cULus | Yes | Yes | Yes | Yes | Yes | |
FM approval | Yes | Yes | Yes | Yes | Yes | |
RCM (formerly C-TICK) | Yes | Yes | Yes | Yes | Yes | |
Marine approval |
|
|
|
|
| |
| Yes |
| Yes | Yes | Yes | |
Ambient conditions |
|
|
|
|
| |
Free fall |
|
|
|
|
| |
| 0.3 m; five times, in product package | 0.3 m; five times, in product package | 0.3 m; five times, in product package | 0.3 m; five times, in product package | 0.3 m; five times, in product package | |
Ambient temperature during operation |
|
|
|
|
| |
| -20 °C to +60 °C horizontal mounting, -20 °C to 50 °C vertical mounting, 95% humidity, non-condensing | -20 °C to +60 °C horizontal mounting, -20 °C to 50 °C vertical mounting, 95% humidity, non-condensing | -20 °C to +60 °C horizontal mounting, -20 °C to 50 °C vertical mounting, 95% humidity, non-condensing | -20 °C to +60 °C horizontal mounting, -20 °C to 50 °C vertical mounting, 95% humidity, non-condensing | -20 °C to +60 °C horizontal mounting, -20 °C to 50 °C vertical mounting, 95% humidity, non-condensing | |
| -20 °C | -20 °C | -20 °C | -20 °C | -20 °C | |
| 60 °C | 60 °C | 60 °C | 60 °C; Number of simultaneously activated outputs: 8 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 16 at 55 °C horizontal or 45 °C vertical | 60 °C; Number of simultaneously activated outputs: 4 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 at 55 °C horizontal or 45 °C vertical | |
| 5°C to 55°C, 3°C / minute | 5°C to 55°C, 3°C / minute | 5°C to 55°C, 3°C / minute | 5°C to 55°C, 3°C / minute | 5°C to 55°C, 3°C / minute | |
Ambient temperature during storage/transportation |
|
|
|
|
| |
| -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | |
| 70 °C | 70 °C | 70 °C | 70 °C | 70 °C | |
Air pressure acc. to IEC 60068-2-13 |
|
|
|
|
| |
| 660 hPa | 660 hPa | 660 hPa | 660 hPa | 660 hPa | |
| 1 080 hPa | 1 080 hPa | 1 080 hPa | 1 080 hPa | 1 080 hPa | |
Relative humidity |
|
|
|
|
| |
| 95 % | 95 % | 95 % | 95 % | 95 % | |
Connection method |
|
|
|
|
| |
required front connector | Yes | Yes | Yes | Yes | Yes | |
Mechanics/material |
|
|
|
|
| |
Enclosure material (front) |
|
|
|
|
| |
| Yes | Yes | Yes | Yes | Yes | |
Dimensions |
|
|
|
|
| |
Width | 45 mm | 70 mm | 45 mm | 70 mm | 45 mm | |
Height | 100 mm | 100 mm | 100 mm | 100 mm | 100 mm | |
Depth | 75 mm | 75 mm | 75 mm | 75 mm | 75 mm | |
Weights |
|
|
|
|
| |
Weight, approx. | 210 g | 310 g | 230 g | 350 g | 230 g |