智能制造网

登录

测试与监控(老分类)工控仪表仪器压力仪表

516.11 WIKA 516.11 516.12 绝压表 波登管或膜盒式 标准型 80表圆

供应商:
卓尔瑞华(北京)科技有限公司
企业类型:
代理商

产品简介

WIKA 516.11 516.12 绝压表 波登管或膜盒式 标准型 80表圆

详细信息

 

类型: 真空压力表 联接型式: 多种连接
型号: 516.11,516.12 精度等级: 1.6
品牌: WIKA/威卡 环境温度: 00(℃)
加工定制: 公称直径: 80(mm)
测量范围: 0-1000mbar(MPa)    

WIKA 516.11 516.12 绝压表 波登管或膜盒式 标准型 80表圆,

AbsoIute Pressure Gauges
Compact Design
With Capsule Element • Model 516.11
With Bourdon Tube • Model 516.12



   Service intended
    Measurement of absolute pressure excluding the effect of barometric pressure variation.
    Suitable for all clean and dry gaseous media that will not attack copper alloy and aluminium parts.


   Design
    Small compact design, varied possibility for installation, WIKA trade pattern DT-GM 87 10 226 Variable pressure entry


   Nominal size
    80 mm


   Accuracy class per EN 837-3 /6
    1.6


   Scale ranges per EN 837-3 /5
    Model 516.11: 0 ... 16 to 0 ... 1000 mbar absolute pressure
    Model 516.12: 0 ... 1.6 to 0 ... 16 bar absolute pressure.


   Working pressure
    Steady: full scale value
    Fluctuating: 0.9 x full scale value


   Overpressure safety
    Model 516.11: 1 bar absolute (atmospheric pressure) with all scale ranges
    Model 516.12: full scale value


   Operating temperature
    Ambient: -20 ... +60 °C
    Medium: +70 °C maximum


   Temperature error
    Additional error when temperature of the pressure element deviates from +20 °C
    Rising temperature: +0.3%/10 K of true scale value
    Falling temperature: -0.3%/10 K of true scale value


   Degree of protection
    IP 66 per EN 60 529 / IEC 529


   Standard features
    Pressure connection (exposed to pressure medium)
    Threaded entry per EN 837-1 /7.3
    G E female


   Pressure element (exposed to pressure medium)
    Model 516.11: Material Cu-alloy
    Model 516.12: Material stainless steel
    The pressure element is evacuated and constitutes pressure datum

 

 

 

   Movement (exposed to pressure medium)
    Material: Cu-alloy


   Dial (exposed to pressure medium)
    White aluminium with black lettering


   Pointer (exposed to pressure medium)
    Black aluminium pointer

 

 

 

   Zero adjustment
    Adjusting provisions at case back (model 516.11)


   Case (exposed to pressure medium)
    Black aluminium. Case retains process pressure


   Window (exposed to pressure medium)
    Instrument glass


   Sealing rings (exposed to pressure medium)
    NBR (Buna rubber)


   Bezel ring
    Black aluminium


   Gauge mounting
    Requires mounting by means of rigid tailpipes, optionally threaded studs at case back.
    Panel mounting or surface mounting rings optionally available


   Optional extras
    Other pressure connection
    Mounting studs with bracket
    Panel mounting ring
    Surface mounting ring
    Male thread pressure entry
    Pressure entry with miniature flange DN 10/16 to DIN 28 403
    Radial pressure entry other than bottom


   Operating principle
    - The case machined from solid aluminium bar retaines the system pressure, whereas the pressure element of either the capsule or the bourdon tube type constitutes the zero pressure datum.
    - The particularly shaped capsule fully collapses to provide over-pressure safety independent of the scale range.
    - Any pressure applied is measured against the sealed pres sure datum to exclude the effect of ambient pressure variation.

 

 

 

   Dimensions
    Standard version

   

   Ordering information
    State:
    Model / Nominal size / Scale range / Size and location of connection / Optional extras required

 

   

 

在线询价