Nicomp 380 DLS 纳米激光粒度仪

供应商:
奥法美嘉科技有限公司
企业类型:
其他

产品简介

DynamicLightScatteringTheNicomp380SubmicronParticleSizeAnalyzerusestheprincipleofDynamicLightScattering(DLS)toobtainthepartcilesizedistributionofcolloidalsystemswhosesizesrangefrom0

详细信息

  • Dynamic Light Scattering

    Nicomp-2.jpg

    The Nicomp 380 Submicron Particle Size Analyzer uses the principle of Dynamic Light Scattering (DLS) to obtain the partcile size distribution of colloidal systems whose sizes range from 0.5 nanomters to 6 microns. DLS works by illuminating a group of particles in suspension with a focused laser beam which gives rise to many scattered light waves. These waves interfere with each other and produce a net scattered intensity that fluctuates as a function of time at some distant detector. Diffusion, or Brownian motion, of the particles causes random variations in the phases of the individual waves, resulting in a fluctuating light intensity. The particle size distribution can be obtained by analyzing the time behavior of these fluctuations using an autocorrelator. The autocorrelation function for a single uniform size distribution is a decaying exponential function where particle diffusivity is easily obtained from the decay time. Finally the particle radius can easily be calculated using the Stokes-Einstein relationship.

    In general most samples are not uniform instead they are quite often polydisperse, having a range of particle sizes. The autocorrelation function then consists of a combination of decaying exponential functions, each having a different decay time and the analysis of the autocorrelation function is no longer quite simple. The instrument using varying deconvolution algorithms must invert the raw data in order to arrive at the best estimate of the true particle size distribution. The Nicomp excels at characterizing these difficult particle size distributions by utilizing a group of unique deconvolution algorithms ranging from a simple Gaussian approximation to a proprietary high resolution multi-modal deconvolution analyses called the “Nicomp Distribution".

    Some of the unique features found on Gaussian analysis mode is a baseline adjust parameter which provides aggregate compensation that excedes the sensitivity found on most other instruments which employ a dust or dirt factor. The Gaussian analysis mode also allows for the user to specify a solid or vesicle weighting mode for analysing thin walled colloidal systems like liposomes. The Nicomp Analysis Mode is a proprietary high-resolution deconvolution algorithm that was first introduced over 25 years ago. It has historically proven its ability to accurately analyze even the most difficult closely spaced bimodals (e.g. 2:1 apart) and even certain trimodal distributions. This is extremely useful in finding the native peak of the aggregate distribution.


    The standard Nicomp 380 is equipped with a 12 mW laser diode and PMT detector with an optical fiber set to 90°. Sample is introduced with drop-in cells.

    The 380 is the only Dynamic Light Scattering Instrument designed using a modular approach. Its capabilities may be enhanced by adding one or more modules:

    Autodilutio

    This patented module eliminates the need for manual dilution of concentrated sample. Autodilution makes particle size analysis quick and easy, with no training required. Results are highly reproducible.

    380/HPLD High Power Laser Diodes

    PSS offers an array of high power laser diodes to meet the needs of our most demanding applications. Higher power lasers are needed to extend the lower limit of our instrument by providing adequate scattering from small particles. They are also useful when measuring large particles such as dextrans, which yield insufficient scattering intensity because of index of refraction properties. The result is a more versatile instrument, ideal for sizing microemulsions, surfactant micelles, proteins and other macromolecules. It can even estimate the extent of aggregration of biopolymers after reconstitution, without chromatographic separation.

    Avalanche Photo Diode (APD) Detector

    The Nicomp 380 can be equipped with various high-powered lasers as well as a high-gain Avalanche Photo Diode Detector (APD which provides approximately seven times the gain of a conventional photomultiplier tube. The APD is used to increase signal-to-noise and sensitivity in systems that do not scatter light well. Proteins, micelles, other macro-molecular-based systems, and nanoparticles are often dilute (1 mg/ml or less) and are made of atoms that do not scatter light well. The Avalanche Photo Diode coupled with a nominally higher powered laser diode module offers a low cost solution for accurately analyzing nanoparticles in a short period of time.

    380/MA Multi-angle Goniometer

    Particles larger than 100 nm do not scatter light isotropically in all directions. It is possible to make DLS measurements more sensitive to certain sized particles by changing the angle of detection. The Nicomp 380 can be equipped with a mini-goniometer that moves the optical fiber between 12° and 175° by 0.9° increments.


  • 详情请参考Nicomp 380 N3000。点击跳转

  • 详情请参考Nicomp 380 N3000。点击跳转

  • 详情请参考Nicomp 380 N3000。点击跳转

  • 详情请参考Nicomp 380 N3000。点击跳转

  • 尊敬的用户您好,在对仪器还不了解的情况下,为了让您可以选择一款适合贵单位的设备,可以先寄送样品到我们公司,由我们的技术人员帮您测试样品,并将测试结果和数据报告发送到您邮箱或者将纸质版寄送到贵单位。

    下方链接是测试申请表,请下载填写完整后随样品一起寄送过来。

    下载链接在这里邮寄地址:中国上海闵行区漕河泾浦江高科技园 F区 新骏环路588号23幢402室

    邮编:201204
    :吴先生(请备注样品)
    电话:



  • Nicomp 380 系列彩页
    序号文件类型下载链接
    1PDF_512px_1184255_easyicon.net.png

    PSS_380合集_Brochures_CN_v3.0

    2PDF_512px_1184255_easyicon.net.png

    PSS_N3000_纳米粒度仪_flyer_CN_v4.0

    3PDF_512px_1184255_easyicon.net.png

    PSS_Z3000_纳米粒度及Zeta电位分析仪_flyer_CN_v4.0

    4PDF_512px_1184255_easyicon.net.png

    PSS_Nicomp_3000_粒度分析仪系列_Brochures_V4.4



    AccuSizer 780 系列彩页
    序号文件类型下载链接
    1PDF_512px_1184255_easyicon.net.png

    PSS_780合集_Brochures_CN_v3.0

    2PDF_512px_1184255_easyicon.net.png

    PSS_不溶性微粒专题_flyer_CN_v3.0

    3PDF_512px_1184255_easyicon.net.png

    PSS_粒度仪在医药行业的应用_flyer_CN_v3.0

    4PDF_512px_1184255_easyicon.net.png

    PSS_A2000_SIS_不溶性微粒检测仪_flyer_CN_v4.0

    5PDF_512px_1184255_easyicon.net.png

    PSS_A7000_APS_大乳粒检测仪_flyer_CN_v4.0

    6PDF_512px_1184255_easyicon.net.png

    PSS_A7000_AD_多功能自动计数粒度仪_flyer_CN_v4.0

    7PDF_512px_1184255_easyicon.net.png

    PSS_FMS_flyer_CN_v3.0

    8

    PDF_512px_1184255_easyicon.net.png

    PSS_AccuSizer_2000_不溶性微粒分析仪系列_Brochures_V4.4

    9PDF_512px_1184255_easyicon.net.pngPSS_AccuSizer_7000_计数粒度分析仪系列_Brochures_V4.4
    10PDF_512px_1184255_easyicon.net.pngPSS_AccuSizer_9000_高浓度纳米颗粒计数器系列_Brochures_V4.4
    11PDF_512px_1184255_easyicon.net.pngPSS_FMS_在线粒度仪系列_Brochures_V4.4






  • 在线询价